Medical inspection equipment – 8" ECG monitor
0
8" ECG monitor
1、 Performance characteristics of multi parameter monitor: | ||||||||||||||||
1. Using world famous brand module, high precision, accurate parameters, reliable quality and stable performance 2. High brightness and high resolution 8 inch color TFT liquid crystal display, data waveform is clear and easy to see 3. Light and strong body, easy to carry 4. Internal all metal structure, fully isolated floating ground, parameters more stable and reliable 5. Rotary flying edge operation mode, Chinese and English operation interface, easy to learn, easy to use, easy to operate 6. LFG full digital light frequency blood oxygen measurement technology, pulse oxygen saturation measurement more accurate 7. Full lead seven channel synchronous display ECG 8. Five minute ECG waveform playback, ST segment automatic detection, arrhythmia analysis, drug concentration calculation, respiratory oxygenation diagram and other functions 9. Full parameter 384 hours trend data memory and dynamic waveform capture 10. The upper and lower limits of alarm can be set at will, and the automatic sound and light double alarm can be set 11. It is suitable for adults, children and newborns 12. Anti defibrillation, anti high frequency electrotome interference 13. With the function of network transmission, the cable can be directly connected with the computer or send data packets through the network 14. Ultra quiet, fanless design 15. Standard configuration plug-in lithium battery, both AC and DC 16. Optional built-in dual channel thermal array recorder, real-time printing waveforms and charts 17. It can be equipped with VGA function interface and external large screen display 18. It is widely used in internal medicine, surgery, operating room, obstetrics and Gynecology, pediatrics, emergency center, ICU, CCU | ||||||||||||||||
ECG | ||||||||||||||||
Lead selection: | Full lead, I, II, III, AVF, AVR, AVL, V1 -- 6 chest lead display | |||||||||||||||
Gain selection: | ×1 、×2 、×4、×0.5 | |||||||||||||||
Frequency: | Diagnosis mode: 0.05 ~ 130Hz | |||||||||||||||
Monitoring mode: 0.5 ~ 40Hz | ||||||||||||||||
Operation mode: 1 ~ 20Hz | ||||||||||||||||
Common mode signal suppression: | diagnostic mode > 90 dB | |||||||||||||||
Monitoring mode > 100 dB | ||||||||||||||||
Operation mode > 100 dB | ||||||||||||||||
Scanning speed: | 12.5 mm / s, 25 mm / s and 50 mm / s. | |||||||||||||||
Heart rate range: | adults 15-300bpm (beats / min) | |||||||||||||||
Neonatal / child: 15-350 BPM (beats / min) | ||||||||||||||||
Heart rate accuracy: | ± 1% or ± 1bpm, whichever is greater | |||||||||||||||
Calibration signal: | 1mV (peak value, accuracy ± 5%) | |||||||||||||||
ST segment detection: | measurement range (- 2.0MV ~ + 2.0MV) | |||||||||||||||
Baseline recovery time: | < 3 seconds after defibrillation | |||||||||||||||
Alarm mode: | sound and light alarm | |||||||||||||||
Preset range of heart rate alarm: (alarm when exceeding preset value) | The upper limit is adjustable between 40 and 255 times / min | |||||||||||||||
The lower limit is adjustable between 20 and 160 times / min | ||||||||||||||||
Resp breathing | ||||||||||||||||
Respiratory measurement range: | adult 7-120 brpm (times / min) | |||||||||||||||
Children and newborns: 7-150 brpm (times / min) | ||||||||||||||||
Accuracy: | +/- 2 brpm (times / min) | |||||||||||||||
Resolution: | 1 brpm (time / min) | |||||||||||||||
Gain selection: | × 0.5, × 1, × 2, × 4 | |||||||||||||||
Alarm mode: | sound and light alarm | |||||||||||||||
Alarm preset range: (alarm when exceeding preset value) | The upper limit is adjustable between 10 and 100 times / min | |||||||||||||||
The lower limit is adjustable from 0 to 99 times / min | ||||||||||||||||
NIBP blood pressure | ||||||||||||||||
Technique: | oscillography (pulse wave oscillation) | |||||||||||||||
Working mode: | manual / automatic | |||||||||||||||
Measurement unit: | mmHg / kPa | |||||||||||||||
Over voltage protection: | double safety protection | |||||||||||||||
Adult mode: 300 mmHg | ||||||||||||||||
Child mode 240 mmHg | ||||||||||||||||
Neonatal mode: 150 mmHg | ||||||||||||||||
Blood pressure measurement range and accuracy: | adult | Systolic blood pressure was 40-270mmhg | ||||||||||||||
Diastolic blood pressure was 10-215mmhg | ||||||||||||||||
The average pressure is 20-235 mmHg | ||||||||||||||||
children | Systolic blood pressure was 40-200mmhg | |||||||||||||||
Diastolic blood pressure was 10-150 mmHg | ||||||||||||||||
The average pressure is 20-165mmhg | ||||||||||||||||
newborn | Systolic blood pressure was 40-135mmhg | |||||||||||||||
Diastolic blood pressure was 10-100mmhg | ||||||||||||||||
The average pressure is 20-110mmhg | ||||||||||||||||
Static pressure range: | 0 ~ 300MMHG | |||||||||||||||
Static pressure accuracy: | +/- 3mmHg | |||||||||||||||
Blood pressure accuracy: | the maximum average error was +/- 5 mmHg; | |||||||||||||||
the maximum standard deviation was 8 mmHg | ||||||||||||||||
Alarm mode: | sound and light alarm | |||||||||||||||
Alarm preset range and error: (alarm when exceeding preset value) | The upper limit of systolic blood pressure is 40-250mmhg; the lower limit is 10-220mmhg | |||||||||||||||
The upper limit of diastolic blood pressure is 20-250mmhg; the lower limit is 10-220mmhg | ||||||||||||||||
SpO2 blood oxygen saturation | ||||||||||||||||
Range: | 70-100%: +/- 2 digit | 0% ~ 69%: not defined | ||||||||||||||
Oxygen saturation measurement error: | 70-100%: +/- 2 | 0% ~ 69%: not defined | ||||||||||||||
Resolution: | 1% | |||||||||||||||
Pulse frequency: | 20-300 times / min | |||||||||||||||
Alarm mode: | sound and light alarm | |||||||||||||||
Alarm preset range and error: (alarm when exceeding preset value) | The upper limit is 20% - 100%; | |||||||||||||||
The lower limit is 10% - 99%; | ||||||||||||||||
Temp temperature | ||||||||||||||||
Technology: | high sensitive thermistor probe | |||||||||||||||
Temperature measurement range: | 0 ℃~ 45 ℃ | |||||||||||||||
Resolution: | 0.1 ℃ | |||||||||||||||
Temperature accuracy: | +/- 0.1℃ (excluding sensor error) | |||||||||||||||
Alarm mode: | sound and light alarm | |||||||||||||||
Alarm preset range and error: (alarm when exceeding preset value) | The upper limit is adjustable between 20.1 ℃ and 45 ℃ | |||||||||||||||
The lower limit is adjustable between 20 ℃ and 44.9 ℃ | ||||||||||||||||
data storage | ||||||||||||||||
It can transfer the data in the machine to the computer through the network cable, or send the data package to the user platform for storage and sharing | ||||||||||||||||
Power Supply | ||||||||||||||||
Built in battery (standard): fully sealed and maintenance free super large capacity lithium battery External AC: single AC power supply is 220 V, 50 Hz, and the maximum current is 1a Working temperature: 5 ℃~ 40 ℃ Working humidity: ≤ 85% relative humidity, no condensation Storage temperature: - 20 ℃~ + 55 ℃ Storage humidity: ≤ 95% relative humidity, no condensation Altitude: 86.0 kPa ~ 106.0 kPa (working state) Power consumption: no more than 70va | ||||||||||||||||
Monitor size and weight Dimensions: 320mm x 280mm x 190mm Weight of finished product: 6kg | ||||||||||||||||
safety standards Comply with iec60601-1, ul2601 medical international safety standards It meets the requirements of national and industrial standards GB9706.1-2007, gb9706.9-2008, gb9706.25-2005, yy0667-2008, yy0668-2008, yy0709-2009 and yy0784-2010. | ||||||||||||||||
Matching End tidal carbon dioxide bypass mainstream | ||||||||||||||||